Ngwaahịa
Pịnye A Residual Current Circuit Breaker
  • Pịnye A Residual Current Circuit BreakerPịnye A Residual Current Circuit Breaker
  • Pịnye A Residual Current Circuit BreakerPịnye A Residual Current Circuit Breaker
  • Pịnye A Residual Current Circuit BreakerPịnye A Residual Current Circuit Breaker

Pịnye A Residual Current Circuit Breaker

Zụrụ CDADA Ụdị A Residual Current Circuit breaker si Shanghai DADA Electric, anyị nwere ihe karịrị 40 afọ ahụmahụ, nwere ike ịbụ gị soplaya. EN/IEC 61008-1 kwadoro, 2P/4P, 16-100A, 30mA/100mA nhọrọ. Na-achọpụta mpụta AC + na-akpali akpali DC. IP20, DIN okporo ígwè okporo ígwè, ịwa na-eguzogide. Kwesịrị ekwesị maka ụlọ ọgbara ọhụrụ & ogwe azụmahịa.

Gbaa mbọ hụ na nchekwa nkeonwe na ọkụ zuru oke na gburugburu igwe elektrọnik taa nwere CDADA Ụdị A Residual Current Circuit Breaker (RCCB), anyị nwere ike ịnye ọnụahịa ụlọ nrụpụta ozugbo. Ọ na-agafe nchọpụta nke ntanaka AC nke bụ isi-ọ na-awụlikwa elu na ma sinusoidal AC yana mmiri mmiri na-agbapụta DC na-emepụta site na ngwa ndị a na-ahụkarị dịka chaja ekwentị, ndị ọkwọ ụgbọala LED, kọmputa, na ngwa ngwa ngwa ngwa.

Ọ dị na nhazi 2P (1+N) na 4P (3+N) nwere oke mmiri sitere na 16A ruo 100A na mmetụta nke 10mA, 30mA, 100mA, ma ọ bụ 300mA, emebere ya maka ebe obibi, ụlọ ọrụ, na nrụnye azụmahịa ọkụ.

Site na ọkwa mkpirisi okirikiri 6kA, nchekwa IP20, yana nhọrọ ọnụọgụ abụọ (lug/pin), CDADA Ụdị A RCCB na-ejikọta nchekwa, ntụkwasị obi, na nhazi enyi na enyi-ha niile na-akwado nkwado zuru ụwa ọnụ.

Type A Residual Current Circuit Breaker

Nkọwapụta igodo

Ụdị ngwaahịa: Pịnye A RCCB (nke fọdụrụ ugbu a sekit Breaker na-enweghị nchebe gabiga ókè)
Ọkọlọtọ: EN/IEC 61008-1
Osisi: 2P (1+N) ma ọ bụ 4P (3+N)
Enyere aha ugbu a (N'ime): 16A, 25A, 32A, 40A, 63A, 80A, 100A
Ogo voltaji: 2P:
230V AC 4P:
230/400V AC Mmetụta fọdụrụnụ (I△n):
10mA, 30mA, 100mA, 300mA Ugbu a anaghị eme njem:
0.5 × I△n Oge njem na I△n:
≤ 0.1 sekọnd Ọnọdụ Mkpirisi okirikiri ugbu a (Inc):
6kA Ime na imebi ikike (I₄m):
500A (maka na ≤ 40A)
630A (maka na ≥ 63A)
Ịnagide voltaji (Uimp):
6000V Okpomọkụ na-arụ ọrụ:
-25°C ruo +40°C Ogo nchekwa:
IP20 Ịkwanye:
35mm DIN okporo ígwè (EN 60715 kwadoro) Ọnụ ụzọ:
Ụdị akpa ma ọ bụ pin, na-akwado eriri ruo 35mm² Ihe ngosi onyonyo:
Red = ON (kọntaktị mechiri), Green = Gbanyụọ (kọntaktị meghere) Usoro njem:
Mwepụta elektrọnik - enweghị mgbanwe voltaji


Kedu ihe kpatara ịhọrọ CDADA Ụdị A RCCB?

★  Na-achọpụta ihe iyi egwu mgbapụ n'ụwa

N'adịghị ka ụdị AC ngwaọrụ ndị bụ isi, CDADA Ụdị A na-anabata ma AC na pulsating DC-dị mkpa maka nchekwa n'ụlọ na ụlọ ọrụ jupụtara na ọkụ ọkụ mode, inverters, na EV chaja.

★ Ọ dịghị mkpagharị njem

Nzacha dị elu na-eme ka ọ bụrụ ihe mgbochi na spikes voltaji na mmiri na-agafe agafe na-adịghị emerụ ahụ, ebe ọ ka na-ekwe nkwa <0.1s oge njem na njiri mara ọkwa.

★ Kpochapụ Ọnọdụ Anya

Ngosipụta ọnọdụ kọntaktị na-acha uhie uhie/acha ndụ ndụ na-enye ohere nkwenye ozugbo nke steeti mebiri-dị oke mkpa n'oge mmezi ma ọ bụ nlele mberede.

★ Flexible Wiring & High ndakọrịta

Na-akwado ọdụ ma ọ bụ pin na eriri 35mm², na-eme ka ọ dakọtara na bọsbars na ndị na-eduzi mgbanwe na ogwe ọgbara ọhụrụ.

Type A Residual Current Circuit Breaker

★ Abụọ ọzọ rivet

ụbara ike nke casing na mpaghara njikọ njikọ n'ihi rivets abụọ ọzọ na ihu ihu siri ike

Type A Residual Current Circuit Breaker

★ DIN okporo ígwè mwekota

Ntinye ngwa ngwa na ntụkwasị obi ọzọ nke snapping na ụgbọ okporo ígwè DIN n'ihi latch nwere mkpọchi okpukpu abụọ

Type A Residual Current Circuit Breaker

★ Nkwado zuru ụwa ọnụ, Uru Mpaghara

Asambodo na IEC/EN 61008-1, dabara maka EU, Middle East, Africa, na Asia ahịa — na ọnụahịa asọmpi sitere n'aka onye nrụpụta China a pụrụ ịdabere na ya.

Type A Residual Current Circuit Breaker

Ngwa a na-ahụkarị

Type A Residual Current Circuit BreakerỤlọ ọgbara ọhụrụ: sekit oghere nwere TV, laptọọpụ, ngwa eletrọnịkị kichin

Type A Residual Current Circuit BreakerỤlọ ọrụ: ọnụ ụlọ IT, eriri ike arụ ọrụ

Type A Residual Current Circuit BreakerAhịa: Sistemụ POS, akara dijitalụ, ọkụ ọkụ

Type A Residual Current Circuit BreakerEbe Nchaji EV: oyi akwa nchekwa bụ isi (jikọtara ya na ngwaọrụ karịrị akarị)

Type A Residual Current Circuit BreakerNrụnye enwere ike imeghari: Ndị na-atụgharị anyanwụ na-emepụta ntapu DC pulsed

Type A Residual Current Circuit Breaker

FAQ

Q1: Kedu ihe dị iche n'etiti Ụdị A na Ụdị AC RCD?

A1: Ụdị AC na-achọpụta naanị ụcha sinusoidal AC dị nro. Ụdị A na-achọpụta ma AC na DC na-emegharị emegharị (dịka ọmụmaatụ, site na ndị na-emegharị na chaja ekwentị, ndị ọkwọ ụgbọala LED, ma ọ bụ igwe ịsa ákwà). Maka sekit ọ bụla nwere ngwa eletrọnịkị, koodu eletrik ọgbara ọhụrụ chọrọ Ụdị A.


Q2: Ụdị 30mA A RCD ezuola maka nchebe onwe onye?

A2: Ee. 30mA bụ ọkọlọtọ ọkọlọtọ maka nchekwa ujo na-azọpụta ndụ kwa IEC. Ụdị CDADA A na-achọpụta na ọ na-arụ ọrụ ọ bụrụgodị na mmejọ ahụ gụnyere DC components-eme ka ọ dị nchebe karịa Ụdị AC na ọnọdụ ụwa n'ezie.


Q3: RCCB a ọ na-enye oke ibu ma ọ bụ nchebe obere oge?

A3: Mba. Nke a bụ RCCB dị ọcha (enweghị nchebe na-agafe agafe). A ghaghị iji ya mee ihe n'usoro na MCB ma ọ bụ fuse iji chebe ibu ibu na obere sekit.


Q4: Enwere m ike iji ya na TT earthing usoro?

A4: Ee-Ụdị A Residual Current Circuit Breakers na-ejikarị na sistemụ TT, ọkachasị na 100mA ma ọ bụ 300mA maka nchekwa ọkụ na onye na-enweta ego, yana 30mA maka sekit ikpeazụ.


Q5: Gịnị kpatara ịhọrọ CDADA karịa ụdị A ndị ọzọ?

A5: CDADA na-enye:

● Ezi IEC 61008-1 nnabata na akụkọ nyocha

● Nhọrọ ọnụọgụ abụọ (lug/pin) maka wiwi na-agbanwe agbanwe

● Ọkwa kọntaktị agbadoro agba (acha uhie uhie / akwụkwọ ndụ akwụkwọ ndụ)

● Ịwa ahụ nke na-alụso ọrịa ọgụ—ọ dịghị njem ụgha

● OEM-njikere: nnukwu ọnụahịa, akwụkwọ Bekee, nlele ngwa ngwa

Type A Residual Current Circuit Breaker



Mkpado na-ekpo ọkụ: Pịnye A Residual Current Circuit Breaker, China, Onye nrụpụta, Onye na-ebubata ihe, Ụlọ ọrụ
Zipu ajụjụ
Ozi kọntaktị

Mepee ngwọta eletriki omenala gị n'ime awa 24!

Kedu ihe kpatara ị ga-eji jụọ onye nrụpụta China kacha elu?

✅ Ọnụ ahịa ụlọ ọrụ ozugbo

Belata ọnụ ahịa etiti! Dị ka ụlọ ọrụ ISO 9001 kwadoro na China, anyị na-ebuga MCCBs, MCBs, na anyanwụ DC breakers na ọnụego asọmpi-nke CE, KEMA, na ASTA kwadoro.

✅ Afọ 40+ nke ọkachamara OEM / ODM

Gbanwee casings, labelụ, ma ọ bụ nkọwa nka na-agba mbọ. Ndị otu R&D anyị (patent 60+) jikwaa:

Ụdị voltaji/nke dị ugbu a

Nkwakọ ngwaahịa akara

Ngwa ngwa prototyping (nlele n'ime ụbọchị 7)

✅ Ikike nkeji 3 nde + kwa afọ

Enweghị iwu buru oke ibu ma ọ bụ ngwa ngwa! Ihe ọkụkụ 52,400㎡ anyị na-ekwe nkwa:

◆ Oge ụzọ ụbọchị 15 maka nnukwu iwu

◆ MOQs na-agbanwe agbanwe

◆ Nnwale ASTM/UL siri ike

✅ Nkwekọrịta zuru ụwa ọnụ, nsogbu efu

Anyị na-edozi ihe mgbochi mbupụ maka mba 45+:

Akwụkwọ RoHS/REACH

Asambodo mpaghara akọwapụtara

Anyanwụ DC breakers maka EU akwụkwọ ndụ akwụkwọ ndụ ọrụ

X
Anyị na-eji kuki iji nye gị ahụmịhe nchọgharị ka mma, nyochaa okporo ụzọ saịtị na hazie ọdịnaya. Site na iji saịtị a, ị kwenyere na ojiji anyị ji kuki.amụma nzuzo
JụNabata